logo
Dom ProduktyCzujnik gazu tlenowego

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Orzecznictwo
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Im Online Czat teraz

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration
YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Duży Obraz :  YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Szczegóły Produktu:
Miejsce pochodzenia: Brytania
Nazwa handlowa: YJJ
Numer modelu: 4OXV AAY80-390-CN 4OX-V
Zapłata:
Minimalne zamówienie: 1
Cena: negocjowalne
Szczegóły pakowania: Paletyzowane
Czas dostawy: 5-8 dni
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, Moneygram
Możliwość Supply: 2200

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Opis
Zasada działania: Zasada elektrochemiczna Zakres pomiaru‌: 1 - 25% obj. O₂
„Maksymalne przeciążenie”.: 30% obj. O₂ ‌ SygnałPut ‌: 0,10 ± 0,02 mA w powietrzu
„Czas reakcji (T90)‌: <15 sekund Prąd zerowy (odchylenie).: < 0,6% obj. O₂
‌ linearii ‌: W większości przypadków ogólnie uważane za liniowe ‌ Temperatura operacyjna‌: -20 ° C do +50 ° C.
Podkreślić:

electrochemical oxygen sensor 0-30% range

,

oxygen gas sensor ambient measurement

,

YJJ 4OXV oxygen sensor with warranty

Product Description:

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

 

Features:

Oxygen sensor 4OXV technical parameters

measurement

How it works: electrochemistry

Measurement range: 1-25% O2

Maximum overrun range: 30%

Signal output: 0.1 0.02mA

Response time (T90) : < 15s

Zero drift: < 0.6% O2

-ity: many cases can be regarded as -, see the specific data

 

Electrical parameters

Load resistance: 100 Ω

 

The mechanical parameters

Weight: < 16g

Shell material: ABS

 

Using the environment

Use temperature: - 20 to 50 ℃

Temperature: 0-20 ℃

Thermal transient: < 23.5% O2

Pressure: atmospheric pressure 20%

Pressure coefficient: < 0.02%/mBar

Pressure transient: < 200% signal change

Humidity: 5-95%RH non-condensing, short term up to 0-99% non-condensing

 

life

Long-term sensitivity drift: < 2%/ month

< 5%/ year typical value

Use time: 2 years

Storage time: 6 months

 

Specifications:

Load resistance 100 Ω
Maximum overrun range 30%
Signal output 0.1 0.02mA
Zero drift < 0.6% O2
Load resistance 100 Ω

 

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration 0