logo
Dom ProduktyCzujnik gazu tlenowego

4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Orzecznictwo
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Im Online Czat teraz

4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life
4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life 4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life 4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Duży Obraz :  4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Szczegóły Produktu:
Miejsce pochodzenia: Cn
Numer modelu: 4OX-V-CN 4OXV-CN AAY80-390-CN
Zapłata:
Minimalne zamówienie: 1
Cena: negocjowalne
Szczegóły pakowania: pudełko papierowe
Czas dostawy: 3-5 dni pracy
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, Moneygram
Możliwość Supply: 5000 pne

4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Opis
Zakres pomiaru: 1 - 25% obj. O₂ Maksymalne przeciążenie: 30% obj. O₂
Sygnał wyjściowy: 0,10 ± 0,02 mA w powietrzu Czas reakcji (T90): <15 sekund
Prąd zerowy (przesunięcie): < 0,6% obj. O₂ Współczynnik ciśnienia: < 0,02% sygnału/mbar
Podkreślić:

oxygen gas sensor with false alarm immunity

,

4OXV-CN oxygen sensor reliable lifespan

,

AAY80-390-CN oxygen gas sensor

 

                            4OX-V-CN 4OXV-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

 

 

Features:

  • False alarm immunity.
  • Enhanced response time in extreme applications.
  • Reliably meets stated life.
  • Superior environmental performance.

Applications:

  • General purpose, portable or fixed life safety.

 

Measurement Technology Electrochemical
Measurement Range 1 - 25% vol. O₂
Maximum Overload 30% vol. O₂
Output Signal 0.10 ± 0.02 mA in air
Response Time (T90) < 15 seconds
Zero Current (Offset) < 0.6% vol. O₂
Linearity Can be considered linear in many cases
Operating Temperature Range - 20 °C to + 50 °C (up to 3 months continuous across RH range)
Recommended Storage Temp 0 °C to 20 °C
Thermal Transient < 23.5% vol. O₂ (temp. plunge + 22 °C to - 20 °C)
Operating Pressure Range Atmospheric ± 20%
Pressure Coefficient < 0.02% signal/mbar
Pressure Transient < 200% signal change (60 cm H₂O step change)
Relative Humidity Range (at 0 °C to 20 °C) Continuous: 5 to 95% RH non - condensing; Short term: 0 to 99% RH non - condensing
Recommended Load Resistor 100 Ω
Casing Material ABS
Weight < 16 g
Orientation Sensitivity < 0.2% vol. O₂ equivalent
Long - term Output Drift < 2% signal/month, typically < 5% over operating life

 