logo
Dom ProduktyCzujnik gazu tlenowego

YJJ CLASS R-22MED 0-100% Oxygen Sensor Is Used Anesthesia Machines Medical Oxygen Batteries

Orzecznictwo
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Im Online Czat teraz

YJJ CLASS R-22MED 0-100% Oxygen Sensor Is Used Anesthesia Machines Medical Oxygen Batteries

YJJ CLASS R-22MED 0-100% Oxygen Sensor Is Used Anesthesia Machines Medical Oxygen Batteries
YJJ CLASS R-22MED 0-100% Oxygen Sensor Is Used Anesthesia Machines Medical Oxygen Batteries

Duży Obraz :  YJJ CLASS R-22MED 0-100% Oxygen Sensor Is Used Anesthesia Machines Medical Oxygen Batteries

Szczegóły Produktu:
Miejsce pochodzenia: USA
Nazwa handlowa: YJJ
Numer modelu: KLASA R-22MED
Zapłata:
Minimalne zamówienie: 1
Cena: negocjowalne
Szczegóły pakowania: Paletyzowane
Czas dostawy: 5-8 dni
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Możliwość Supply: 2200

YJJ CLASS R-22MED 0-100% Oxygen Sensor Is Used Anesthesia Machines Medical Oxygen Batteries

Opis
Zakres pomiaru: 0 - 100% o₂ Dokładność: Pod stałą temperaturą
Wyjście sygnału: W powietrzu w temperaturze 25°C Czas reakcji (T90): Mniej niż 6 sekund
Temperatura pracy: 0 - 45 ° C. Temperatura przechowywania: 0 - 25°C. Może
Podkreślić:

YJJ CLASS R-22MED oxygen sensor

,

medical oxygen sensor for anesthesia machines

,

0-100% oxygen sensor with warranty

Product Description:

YJJ CLASS R-22MED 0-100% oxygen sensor is used in anesthesia machines and medical oxygen batteries

 

Features:

CLASS R-22MED oxygen sensor is a high-performance oxygen sensor specially designed for medical applications. Here is a summary of its key parameters:

Measurement range: 0 - 100% O₂

Accuracy: Under constant temperature and pressure conditions, the output accuracy is ±1% of the full scale

Signal output: In 25°C air at 1 standard atmosphere pressure, the output voltage is 8.5 - 14 mV

Response time (T90): Less than 6 seconds, that is, the time from the initial state to reaching 90% of the final value does not exceed 6 seconds

Temperature range:

Operating temperature: 0 - 45°C

Storage temperature: 0 - 25°C, can withstand a short period of up to 55°C during transportation

Humidity range: 0 - 99% RH under non-condensing conditions

Expected lifespan: 42 months

Compatibility: Compatible with various oxygen battery models such as PSR-11-197-MH, MOX-1, OOM-103, GO-12, M-18, MAX-12C, MAX-23, CAT 644, etc.

Protection features: Capable of resisting the long-term impact of nitrous oxide, suitable for modern operating rooms and other medical environments

Origin and assembly: Assembled in the USA (Assembled In USA), with a U.S. patent (U.S. PAT. NO. 5,714,046)

 

Specifications:

Measuring range 0-100% O2
Sensitivity 55 ~ 90nA/ PPM
Response time lt;25s
Full scale - error 15-25ppm

 