YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments

Orzecznictwo
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Im Online Czat teraz

YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments

YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments
YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments

Duży Obraz :  YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments

Szczegóły Produktu:
Miejsce pochodzenia: Brytania
Nazwa handlowa: YJJ
Numer modelu: COCL2 3E 1 1731-031-14049
Zapłata:
Minimalne zamówienie: 1
Cena: negocjowalne
Szczegóły pakowania: W puszkach
Czas dostawy: 5-8 dni
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Możliwość Supply: 2200

YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments

Opis
Zakres pomiaru: 0–3 ppm Maksymalne obciążenie: 3 ppm
Czułość (20 ℃): -0,225 ± 0,075 μA/ppm Czas reakcji (T90): ≤ 90 sekund
Wskaźnik wyjściowy (20°C): <± 0,2 μA Rezolucja: 10 ppb
Napięcie polaryzacji: 0 mV Długoterminowy dryf wyjściowy: < 2% sygnału / miesiąc
Podkreślić:

YJJ COCL2 electrochemical gas sensor

,

gas detection instrument sensor

,

1731-031-14049 gas sensor

Product Description:

YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor for Gas Detection Instruments

 

Features:

COCL2 3E 1
Product features

High-precision electrochemical sensor
The shell design features small holes to restrict the diffusion of gases.
The output signal of the sensor is directly proportional to the concentration within the ppm range.
Technical Specifications

Performance characterization
Gas type Phosgene/COCL2 Product Description
COCL2 3E 1

Sensor Principle - Electrochemistry
Range 0–1 ppm

Maximum load None Sensitivity
650 nA/ppm ± 150 nA/ppm

Zero-point current < ±10 nA

Resolution
0.02 parts per million

Bias 0 mV

Response time (T90) ≤ 120 seconds
Linearity < 10% FS
Long-term stability < 5%/6 months

Working conditions Working temperature

-20 ℃ to 40 ℃

Work humidity
15 to 90%RH (no condensation)
Storage time
6 months (in a dedicated packaging box)
Service life
1 year in the air

 

Specifications:

Zero-point current < ±10 nA
Resolution 0.02 parts per million
Bias voltage 0 mV
Response time (T90) ≤ 120 seconds

 

YJJ COCL2 3E 1 1731-031-14049 Electrochemical Gas Sensor For Gas Detection Instruments 0