logo
Dom ProduktyCzujnik gazu tlenowego

YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices

Orzecznictwo
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Im Online Czat teraz

YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices

YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices
YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices

Duży Obraz :  YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices

Szczegóły Produktu:
Miejsce pochodzenia: Niemcy
Nazwa handlowa: YJJ
Numer modelu: Go-02
Zapłata:
Minimalne zamówienie: 1
Cena: negocjowalne
Szczegóły pakowania: W puszkach
Czas dostawy: 5-8 dni
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Możliwość Supply: 2200

YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices

Opis
Zakres pomiarowy: 0-100% POJ Dokładność: ± 2% fs
Czas reakcji: T90 <15s Sygnał wyjściowy: Sygnał analogowy napięcia
Temperatura pracy: 0 ℃ ~ +45 ℃ Żywotność: 18-24 miesiące
Zgodność: Standardowe piny Drager Delgaer: Evita 2/4/XL
Podkreślić:

YJJ GO-02 electrochemical oxygen sensor

,

medical oxygen gas sensor

,

0-100%VOL oxygen sensor

Product Description:

YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices

 

Features:

I. Basic Information

Model: GO-02 (Medical Specialized Oxygen Sensor Core)

Principle: Galvanic (primary battery) electrochemical principle, no external power supply required, passive sensing of oxygen concentration

Application: Dedicated oxygen battery for Drager Delgaer, Ohmeda GE American Medical Devices ventilators / anesthesia machines, compatible with Envitec OOM201, a medical-grade high-precision oxygen sensor

Alternative Part Number: Drager 6803290/6850645, Ohmeda 6051-0004-001

II. Core Technical Parameters

Measurement Range: 0–100% VOL Oxygen (O₂)

Accuracy: ±2% FS, excellent linearity, medical-grade stability

Response Time: T90 < 15s, rapid sensing of oxygen concentration changes

Output Signal: Voltage analog signal (direct connection to ventilator motherboard)

Operating Temperature: 0°C ~ +45°C (compatible with normal temperature environment of medical equipment)

Service Life: 18–24 months (medical routine conditions)

Compatibility: Standard pins, compatible with mainstream medical equipment from Europe and America

Certification: CE, FDA medical grade compliance certification, safe and reliable

III. Compatible Equipment

Drager Delgaer: Evita 2/4/XL, Fabius anesthesia machine, Babylog 8000 neonatal ventilator

Datex-Ohmeda GE American Medical Devices: Aespire, Avance, S-5 series anesthesia / ventilator

Others: -, Analytical Industries, etc. medical equipment

IV. Main Applications

Medical ventilators: Real-time monitoring of patient inhaled oxygen concentration, precise control of oxygen supply ratio, ensuring safety of critical care, anesthesia, and neonatal ventilation

Anesthesia machines: Monitoring of oxygen content in anesthesia circuit during surgery, preventing hypoxia or oxygen poisoning

Medical oxygen generation equipment: Oxygen concentration detection and alarm for oxygen therapy equipment

Medical monitoring accessories: ICU, operating room, emergency equipment, core component for oxygen concentration monitoring

 

Specifications:

Measurement Range 0–100% VOL
Accuracy ±2% FS
Response Time Response Time
Output Signal Voltage analog signal
Operating Temperature 0℃ ~ +45℃
Service Life 18–24 months

 

YJJ GO-02 0-100%VOL Electrochemical Oxygen Sensor Medical Medical Devices 0

Szczegóły kontaktu
ShenzhenYijiajie Electronic Co., Ltd.

Osoba kontaktowa: Miss. Xu

Tel: 86+13352990255

Wyślij zapytanie bezpośrednio do nas (0 / 3000)