logo
Dom ProduktyMedyczny czujnik przepływu powietrza

281637 282049 282051 Flow sensor For Medical ventilators

Orzecznictwo
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Chiny ShenzhenYijiajie Electronic Co., Ltd. Certyfikaty
Im Online Czat teraz

281637 282049 282051 Flow sensor For Medical ventilators

281637 282049 282051 Flow sensor For Medical ventilators
281637 282049 282051 Flow sensor For Medical ventilators 281637 282049 282051 Flow sensor For Medical ventilators 281637 282049 282051 Flow sensor For Medical ventilators 281637 282049 282051 Flow sensor For Medical ventilators 281637 282049 282051 Flow sensor For Medical ventilators 281637 282049 282051 Flow sensor For Medical ventilators 281637 282049 282051 Flow sensor For Medical ventilators

Duży Obraz :  281637 282049 282051 Flow sensor For Medical ventilators

Szczegóły Produktu:
Miejsce pochodzenia: USA
Numer modelu: 281637 282049 282051
Zapłata:
Minimalne zamówienie: 1PCS
Cena: negocjowalne
Szczegóły pakowania: Standardowe opakowanie
Czas dostawy: 5-8 dni roboczych
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, Moneygram
Możliwość Supply: 5000 pne

281637 282049 282051 Flow sensor For Medical ventilators

Opis
Zakres przepływu: 0 do 180 l/min (krótkoterminowe 260 l/min) Martwa przestrzeń: <11 ml (funkcjonalne)
Opór: <0,027 cmh2o/(l/min) w pełnym zakresie przepływu (-180 l/min do 180 l/min) Temperatura: Działanie: -20 ° C do 50 ° C (-4 ° F do 122 ° F)
Podkreślić:

medical ventilator flow sensor

,

air flow sensor for ventilators

,

medical air flow sensor with warranty

 

                                           281637 282049 282051 Flow sensor For Medical ventilators

 

 

Product Overview:

The 281637 is a compact, industrial-grade gas sensor designed for reliable detection of specific target gases (confirm target gas with manufacturer, e.g., carbon monoxide, methane, volatile organic compounds, or oxygen). It adopts semiconductor (metal oxide) or electrochemical sensing technology (depending on target gas) to deliver fast response, low power consumption, and stable long-term performance. Typical applications include industrial safety monitoring (e.g., factory leak detection), indoor air quality (IAQ) management, smart home safety systems, and portable gas detectors.

 

No.

Component/Parameter Category

Description

Specification/Details

Material

Remarks

1 Connector Ventilator side OD15 PSU -
2 Tubing - - PVC -
3 Connectors for Tubing Differential pressure measurement - PSU -
4 Direction Index - - - -
5 Individual Serial Number - - - -
6 Connector Patient side OD22/ID15 PSU -
7 Flap - - PET -
- Technical Performance Flow range 0 to 180 l/min (short term: 260 l/min) - -
- Technical Performance Dead space < 11 ml (functional) - -
- Technical Performance Resistance < 0.027 cmH₂O/(l/min) over the complete flow range (-180 l/min to 180 l/min) - -
- Technical Performance Weight - Approx. 14 g (without tubes)
- 68 g (with 188 cm tubes)
- 89 g (with 260 cm tubes)
- 110 g (with 330 cm tubes)
- -
- Material Compliance Material standards 1. Complies with ISO 10993-1:2009 (biocompatibility)
2. Complies with Directive 2011/65/EU (RoHS)
3. No natural rubber latex, DEHP, or BPA
- Ensures safety for medical use
- Accuracy (Calibrated Flow Sensor) Volume-related parameters (HAMILTON ventilators) - HAMILTON-C1/T1/MR1/C2/C3/C6: ± 10% or ± 10 ml (whichever is greater)
- HAMILTON-G5/S1: ± 15% or ± 20 ml (whichever is greater)
   

 